Kvaser Memorator Pro, Five Channel Can Bus Interface And Data Logger

SKU: SEW-SW-33101
Unit Price
Quantity
Subtotal
US$ 3,787.16
US$ 3,787.16
US$ 3,764.441%
2
US$ 3,751.141%
3
Congratulations! You got a great price!
Add to cart Added
Checkout
Options
Brand
Barcode
685289331016
Description

Kvaser Memorator Pro 5xHS is a five channel, high performance, CAN (controller area network) bus interface and standalone datalogger that allows users to monitor and collect data from up to five CAN channels using just one device. Standalone mode logs data to an SD card; interface mode connects to the PC via USB. This device supports CAN FD.

Configurable using Kvaser's Memorator Config Tool, Memorator Pro is also capable of running user-developed scripts, written in the Kvaser t programming language. Guidance in creating t programs is supplied.

  • Monitor 5 CAN channels simultaneously using just one device, or connect the USB cable with a single 9 pin DSUB for single CAN channel monitoring.
  • Supports CAN FD, up to 8 Mbit/s (with proper physical layer).
  • Automatically time synchronises the data transmitted and received across all five buses.
  • Built-in Kvaser MagiSync technology time synchronises with other Kvaser interfaces connected to the same PC, resulting in simpler and more accurate multichannel data capture.
  • Script functionality allows users to develop customised t-script applications written in the Kvaser t programming language.
  • Plug and play installation, and a comprehensive user guide to help make t script development quick and easy.
  • Log data to an expandable SD card slot.
  • LED lights alert user to device status, including signalling a full SD card or card error.
  • Power derived from the USB connection, CAN or an in-built power supply.
  • Compatible with J1939, CANopen, NMEA 2000® and DeviceNet.
  • Supports CAN FD.
  • Supported by SocketCAN.
Filters
  • Log continuously, or logging can be triggered by creating advanced triggers based on messages, data signal values, error messages, external trigger's falling or rising edge, and I/O signals.
  • Pre- and post-triggers are available without buffer size restrictions, limited by disk space only.
  • Filter out selectable messages and/or signals to be logged. The identifiers can be picked from a database, or all messages can be logged.
  • Support for pass as well as stop filters.
  • Create a counting pass filter to have a message logged at enumerated occurrence.
  • Handles up to 20,000 msgs/s in standalone logger mode.
  • External digital output that can drive an LED or a buzzer.
  • Supports Silent Mode - Log bus traffic safely without interfering and "listen-only" mode for bus analysis tools
Memory Cards and Functions
  • Easy to use graphic configuration tool - Memorator Tools.
  • Configuration of the CAN controller, i.e. bit rate and filters.
  • Configuration of the trigger conditions.
  • Configuration of filter for messages to be stored.
  • Using the included Kvaser Dispatcher software, a complete measurement setup can be turned into a self-installing package that is sent to a remote location to carry out a specific logging task.
Warranty
  • 2-Year Warranty from Kvaser.
Software
  • Documentation, software and drivers can be downloaded for free at www.kvaser.com/downloads.
  • Kvaser CANLIB SDK is a free resource that includes everything you need to develop software for the Kvaser CAN interfaces. Includes full documentation and many program samples, written in C, C++, C#, Delphi, Java, Python and Visual Basic.
  • All Kvaser CAN interface boards share a common software API. Programs written for one interface type will run without modifications on the other interface types!
  • J2534 Application Programming Interface available.
  • RP1210A Application Programming Interface available.
  • On-line documentation in Windows HTML-Help and Adobe Acrobat format.
Mfg. Part Number
  • 73-30130-00778-9
  • Bitrate: 40-1000 kbps
  • Buffers: Auto RX Buffers, Auto TX Buffers, On Board Buffer
  • Certificates: CE, RoHS
  • Channels: 5
  • Connectors: 26-pin HD D-SUB
  • Current Consumption: Up to 3W
  • Error Counters Reading: Yes
  • Error Frame Generation: Yes
  • Galvanic Isolation: Yes
  • Height: 68 mm
  • Interfaces: USB
  • Length: 170 mm
  • Material: PA66
  • Messages Per Second Receive: 20,000 mps
  • Messages per second sending: 20,000 mps
  • OS: Linux, Win 7, Win Vista, Win 8, Win 10
  • Silent Mode: Yes
  • Sound: No
  • Temperature Range: -40 to 85 °C
  • Timestamp Resolution: 1 µs
  • Weight: 150 g
Shipping specs
Weight
4.81 lbs
Shipping from
This product is shipped from our supplier's warehouse in UT, United States
Our guarantee
This product is brand new and includes the manufacturer's warranty, so you can buy with confidence.
A 25% handling charge is levied against all authorized returns except those due to our error. Unauthorized returns are subject to a 40% handling charge. Damages & defects must be reported to us within 14 days.
LOADING ...
Customers Who Bought This Item Also Bought
You recently viewed items